Surigical Instrument Portable Anesthesia Ventilator Machine
-
Price:
Negotiable
- minimum:
- Total supply:
-
Delivery term:
The date of payment from buyers deliver within days
-
seat:
Beijing
-
Validity to:
Long-term effective
-
Last update:
2017-10-14 01:10
-
Browse the number:
129
Company Profile
BZ Technology Co., Ltd.By certification [File Integrity]
Contact:Ms. Candy Gao(Mr.)
Email:
Telephone:
Phone:
Area:Beijing
Address:Beijing
Website: http://bzgroup123.carverlaser.com/
Product Details
Feature
- Alloy metal stents, spray technology, very durable
- Stainless steel pressure monitoring gauge, the scope: 0-1Mpa, 0.05 scale readable.
- Protective power switch and back-up power interface, effective to eliminate the accident happens.
- New generation veterinary anesthesia ventilator design and architecture platforms
- Professonal veterinary ventilator operation, some parameter could be set automatically.
- Adopt power supply rejection grid anti-jamming technology, more stable performance.
- Good mobility performance,pass vibration test.
- Easy operation, simple and clear.
- International standard interface, could match with any anesthesia machine.
Technical Specification.
1,Drive:Pneumatic driven and electrical control
2, Operation: Button
3,Sensor Type: Rotor sensor
4,Respiratory mode:IPPV,MAN
5,Tidal Volume:50~1600mL
6, I:E: 1:2
8,BPM:3-40bpm
7,TV monitoring:20~300 mL,300 ~2000 mL
8,Airway pressure monitoring:-20-100cmH2O
9, Gas source gauge monitoring :0-1MPa
10, Monitor:Inspiratory indicator,Expiratory indicator,Power indicator
11, Gauge:O2 1
12,Small animal bellows,TV:0~300mL
13, Big animal bellows,TV:300~1600mL
Power supply requirement
1,Power:220V,50HZ or 110V,60HZ
2,Input power: No more than 60VA
3,Maximum input current:5A
4,Main power entrance fuse: 250V 5A φ5X20(F)
Power cable
1,Length:3 meter
2,Rated voltage:90 to 264V AC
3,Maximum current:220 -240VAC 10A
4,Type: three-core cable (medical grade)
2,Rated voltage:90 to 264V AC
3,Maximum current:220 -240VAC 10A
4,Type: three-core cable (medical grade)
Environment requirement
1,Temperature: Operation: 18-36ºC Storage: -20-55ºC
2,Humidifier: Operation: 45%-75% Storage: ≤93%
3,Atmospheric pressure::Operation: 0.95~1.05 bar
Storage:500hpa~1060hpa,
4 Altitude:Operation: 500 to 800 mmHg (3565 to -440m)
Storage:375 to 800 mmHg (5860 to -440m)
Size: 240mm(w)×370mm(H)×230mm(L)
1,Temperature: Operation: 18-36ºC Storage: -20-55ºC
2,Humidifier: Operation: 45%-75% Storage: ≤93%
3,Atmospheric pressure::Operation: 0.95~1.05 bar
Storage:500hpa~1060hpa,
4 Altitude:Operation: 500 to 800 mmHg (3565 to -440m)
Storage:375 to 800 mmHg (5860 to -440m)
Size: 240mm(w)×370mm(H)×230mm(L)
- Biological Products
- Pharmaceutical Chemicals
- Pharmaceutical Intermediate
- Pharmacy Stocks
- Prepared Chinese Medicine
- Western Medicine
- Disabilities
- E-Cigarette
- E-Cigarette Atomizer
- E-Cigarette Starter Kits
- Mini E-Cigarette
- E-Cigarette Battery
- E-Liquid
- Electronic Hookah
- Pen Style E-Cigarette
- Other E-Cigarette & Accessories
- E-Cigarette Cartridges
- E-Pipe
- E-Cigar
- E-Cigarette Charger
- E-Cigarette Bag & Box
- E-Cigarette Drip Tips
- PCC(Portable Charger Case)
- E-Cigarette Lanyard
- E-Cigarette Cable
- Handicap Scooter
- Health Care Appliance
- Massager
- Sex Product
- Weight Management
- Dental Equipment & Supplies
- Medical Equipment
- Medical Implement
- Medical Supply
- Medical-Ray Protective Products